ThePeptideCode LTD
HPLC + MS verified, every batch≥99% purity — independently verifiedFree UK shipping over £100Trustpilot 4.6★ · 60+ reviews
Verified Authentic

Batch verification — CJC-1295 + Ipamorelin

This certificate has been independently verified by an ISO/IEC 17025-aligned laboratory. All analytical data shown below is authentic and matches laboratory records.

PV-63B43A-GNOA-21
Component purity
CJC-1295 no dac98.6%
Ipamorelin99.1%
UV ratio: CJC-1295 17.9% : Ipamorelin 81.0% · HPLC · Blend
Peptide
CJC-1295 + Ipamorelin
Customer
ThePeptideCode
Batch number
BTWF003
Test type
HPLC + LC-MS (Blend)
Molecular weight
CJC-1295 no dac: 3367.2 Da
Ipamorelin: 711.3 Da
MS verification
✓ Confirmed
LC-MS identity verification performed on each component. All components confirmed.

Analysis Summary

Certificate date
02/06/2026
Analysis date
02/06/2026 09:17
Instrument
Shimadzu LCMS-8040
Analysis method
HPLC + ESI-MS
Total peaks
3
Main peak RT
6.496 min
Detected MW
3556.7 Da

Blend Component Analysis

Individual purity assessment for each peptide component in this blend.

ComponentPurity (PPI)Composition (UV)RT (min)TailingPlates (N)
CJC-1295 no dac98.6%17.9%8.4271.9512,982
Ipamorelin99.1%81.0%6.4961.508,173

Reading this table: Purity (PPI) is the spectral homogeneity of each individual peak. Composition (UV) is each peak's share of the total UV signal — not mass or molar ratio. Peptides with strong chromophores (e.g. copper chelates such as GHK-Cu) absorb UV disproportionately, so their UV share can exceed their true mass fraction. Plates (N) is retention-time dependent — peaks eluting near the column void legitimately exhibit lower N values than mid-run peaks on the same column.

Important note

Sample composition reflects UV-detectable compounds only. Non-UV excipients (mannitol, sugars, salts) are not measured by this method.

View Chromatogram & Technical Details
Detection wavelength
214 / 220 nm
CJC-1295 no dac — RT
8.427 min
Ipamorelin — RT
6.496 min
CJC-1295 no dac — plates
12,982
Ipamorelin — plates
8,173
Ionisation
ESI positive

The integrated HPLC chromatogram and annotated ESI-MS mass spectra for each component are included on the full signed Certificate of Analysis, available via the PeptideVerify link above and as a downloadable PDF.

What this verifies
  • Identity confirmed — LC-MS identity verification performed on each component; all components confirmed
  • CJC-1295 (no DAC) peak purity 98.6%; Ipamorelin peak purity 99.1% by RP-HPLC
  • Result issued by an ISO/IEC 17025-aligned independent laboratory
  • Tamper-evident vial sealing under ICH Q7 / WHO GMP-aligned manufacturing
Related pages

Product: CJC-1295 + Ipamorelin · Verification & Testing
Other verified batches: Retatrutide · KLOW80 · GHK-Cu · Tirzepatide

Disclaimer
This certificate reports the analytical findings for the specific sample submitted for testing. Results relate solely to the sample as received and do not extend to other batches or products. Analysis is provided for research and informational purposes only — it does not constitute a safety assessment, medical advice, or endorsement for human or veterinary use.

Verify Batch — CJC-1295 + Ipamorelin (PV-63B43A-GNOA-21) | ThePeptideCode